Summary: TR CU 012/2011 On Safety of Equipment for Use in Explosive Atmospheres
- What is TR CU 012/2011? A mandatory Technical Regulation establishing uniform safety requirements for electrical and non-electrical equipment intended for use in hazardous (potentially explosive) environments within the Eurasian Economic Union (EAEU).
- When is it required? Prior to placing explosion-proof equipment on the market or putting it into operation in Russia, Belarus, Kazakhstan, Armenia, or Kyrgyzstan.
- Mandatory Compliance Document: Equipment falling under this regulation can only be approved via an EAC Ex Certificate (Schemes 1C, 3C, or 4C). EAC Declarations are strictly prohibited for Ex equipment.
- Key Exemption: Standard industrial equipment not designed with explosion protection measures does not fall under TR CU 012/2011, even if installed near hazardous areas.
- Marking Requirements: Certified products must bear both the general EAC conformity mark and the dedicated Ex symbol, alongside a complete EAEU Ex marking string on the nameplate.
- Relationship with EU ATEX & IECEx: Although harmonized with international IEC standards and conceptually similar to EU ATEX Directive 2014/34/EU, TR CU 012/2011 requires Russian-language GOST documentation, local testing, and an EAEU Authorized Representative. ATEX certificates cannot replace EAC Ex certification.
What is TR CU 012/2011?
Technical Regulation TR CU 012/2011 establishes binding safety requirements for electrical and non-electrical equipment operated in potentially explosive gas or dust atmospheres across the Eurasian Economic Union (EAEU). Its primary objective is the protection of human life, health, property, and the environment by reliably preventing explosions and fires caused by industrial equipment.
While the European Union enforces the ATEX Directive 2014/34/EU, the EAEU member states (Russia, Belarus, Kazakhstan, Armenia, and Kyrgyzstan) have established TR CU 012/2011 as their unified legal framework for hazardous locations.
- Adopted on: October 18, 2011 (Customs Union Commission Decision No. 825)
- Entered into force on: February 15, 2013
- End of transition period: March 15, 2015 (all former national standards such as Russian GOST R Ex certificates became permanently invalid)
Equipment intended for potentially explosive environments must be designed and manufactured to prevent ignition of the surrounding atmosphere during normal operation, expected malfunctions, and rare malfunctions (depending on the required Equipment Protection Level), and to withstand explosion pressures and thermal effects safely.
Area of Application of TR CU 012/2011
The regulation strictly defines which products must undergo mandatory conformity assessment and which are excluded. Classification depends on the presence of integrated explosion protection means and intended operation in hazardous zones.
TR CU 012/2011 applies to:
- Explosion-proof electrical equipment, motors, sensors, lighting, and control cabinets;
- Explosion-proof non-electrical equipment (e.g., mechanical devices, pumps, fans, compressors, pneumatic/hydraulic drives, gearboxes, couplings, and valves);
- Ex components intended for integration into explosion-proof equipment (items that do not operate independently but are essential to explosion safety, marked with suffix "U").
TR CU 012/2011 does NOT apply to:
- Medical devices and equipment;
- Devices where explosion hazards arise solely from explosive substances or unstable chemical compounds;
- Household appliances for non-industrial use;
- Personal protective equipment (PPE);
- Seagoing vessels, river barges, mobile offshore platforms, and drilling rigs;
- Public road, rail, air, and water transport vehicles;
- Military equipment, nuclear weapons, and nuclear research facilities.
Key Differences: EU ATEX Directive (2014/34/EU) vs. TR CU 012/2011
International manufacturers holding EU ATEX certificates or IECEx Test Reports (ExTR) should note the core regulatory differences when entering the EAEU market:
| Criterion | EU Practice (ATEX Directive 2014/34/EU) | EAEU Practice (TR CU 012/2011 / EAC Ex) |
|---|---|---|
| Conformity Route | Internal production control (Cat. 3), dossier lodging with Notified Body (Cat. 2 non-electrical), or EU-Type Examination (Cat. 1 / Cat. 2 electrical). | Exclusively mandatory EAC Ex Certification through an accredited EAEU certification body. Self-declaration is prohibited. |
| Applicant / Holder | Manufacturer or EU importer. | Manufacturer, importer, or an EAEU-registered Authorized Representative acting under a formal representation agreement. |
| Quality Audit (QAN) | ISO/IEC 80079-34 audit required for Category 1 and Category 2 (electrical). | Mandatory ISO/IEC 80079-34 manufacturing audit for all serial EAC Ex certificates (Scheme 1C), plus annual surveillance audits. |
| Technical Dossier | Compiled in an official EU language; kept at factory or lodged with Notified Body. | Must be compiled in Russian per GOST standards and actively audited by EAEU Ex experts prior to testing. |
| Nameplate Marking | CE mark + hexagonal Ex symbol + ATEX string (e.g., II 2G Ex db IIC T4 Gb). |
EAC mark + dedicated Ex mark + EAEU Ex string (e.g., 1Ex db IIC T4 Gb X). |
Conformity Assessment Schemes & Mandatory Documentation
Under TR CU 012/2011, the only legally valid approval is an EAC Ex Certificate issued by an accredited certification body based on laboratory testing at an accredited EAEU Ex test center:
- Scheme 1C (Serial Production): Valid for up to 5 years. Requires type testing of samples, an on-site manufacturing quality audit (ISO/IEC 80079-34), and annual inspection control.
- Scheme 3C (Batch / Lot Supply): Valid for a specific contract batch with no expiration date (limited to the batch quantity). Requires sample testing from the batch; no factory audit required.
- Scheme 4C (Single Unit): Valid for one uniquely identified serial-numbered item. Requires testing of the individual unit; no factory audit required.
Mandatory Technical Documentation
Article 6 of TR CU 012/2011 defines strict requirements for the technical dossier, which must be submitted in Russian (and the national language of the EAEU member state where required). Alongside technical drawings, electrical schematics, and the Technical Passport (Ex Passport), the regulation requires:
- Safety Justification (OB): A comprehensive risk analysis evaluating mechanical, electrical, and thermal hazards across the equipment's entire lifecycle.
- Ignition Hazard Assessment: Mandatory especially for non-electrical equipment (GOST 31441.1 / GOST ISO 80079-36), proving the absence of effective ignition sources such as friction sparks or hot surfaces.
- Operation Manual: Must include explicit safety instructions, maintenance intervals, permissible ambient conditions, and rules for safe installation and repair in hazardous zones.
- Existing Certificates & Test Reports: Copies of EU ATEX certificates, IECEx certificates/ExTRs, and ISO 9001 / ISO/IEC 80079-34 certificates (if available).
Marking Requirements according to TR CU 012/2011
Products certified under TR CU 012/2011 must carry both the official EAC conformity mark and the dedicated Ex symbol on the product and accompanying documentation.
Technical Specifications for the EAEU Ex Symbol:
- Composed of stylized letters "E" and "x", where the height of "x" equals 5/9 of the height of "E".
- Minimum symbol height is 10 mm, maintaining an overall height-to-width ratio of 11:8.
- Must be applied on a contrasting background and remain permanent and legible throughout the equipment's service life.
Mandatory Information on the Type Label (Nameplate)
Pursuant to TR CU 012/2011 and harmonized standards (GOST 31610.0 / IEC 60079-0), every explosion-proof device must bear a durable nameplate displaying:
- Name and address of the manufacturer (or registered trademark);
- Product designation (type, model, individual serial number, and year of manufacture);
- Official EAC Mark and Ex Symbol;
- Name or identification number of the accredited EAEU certification body;
- Registration number of the EAC Ex Certificate;
- Complete EAEU Ex Marking string (EPL, protection concept, gas/dust group, temperature class);
- Ingress Protection (IP) rating;
- Ambient temperature range (if outside standard -20 °C to +40 °C).
Decoding the EAEU Ex Marking String
TR CU 012/2011 uses a standardized alphanumeric string to specify where and under what conditions the equipment can be safely operated:
1. Equipment Level of Protection (EPL)
- 0 (Ga / Da / Ma) – Very high level: Remains safe even in the event of two independent rare malfunctions (Zone 0 / Zone 20).
- 1 (Gb / Db / Mb) – High level: Safe in normal operation and expected malfunctions (Zone 1 / Zone 21).
- 2 (Gc / Dc) – Enhanced level: Safe in normal operation with additional protection during expected malfunctions (Zone 2 / Zone 22).
For underground mining equipment (Group I), the Russian designations PO (Very High), PB (High), and RP (Enhanced) are used per GOST 12.2.020-76.
2. Type of Ignition Protection
| Code | Type of Protection | Technical Principle |
|---|---|---|
| d (da, db, dc) | Flameproof enclosure | Contains an internal explosion and prevents flame transmission to the outside atmosphere. |
| e (eb, ec) | Increased safety | Prevents arcs, sparks, and excessive surface temperatures in electrical connections. |
| i (ia, ib, ic) | Intrinsic safety | Limits electrical and thermal circuit energy below the minimum ignition threshold. |
| m (ma, mb, mc) | Encapsulation | Seals potential ignition sources inside a resistant resin compound. |
| p (px, py, pz) | Pressurized enclosure | Maintains a protective gas overpressure inside the enclosure to exclude explosive atmospheres. |
| q | Powder filling | Surrounds live parts with fine quartz or glass powder to quench arcs and flames. |
| o (ob, oc) | Liquid immersion | Immerses potential ignition sources in protective oil or non-flammable liquid. |
| n (nA, nC, nR) | Type of protection "n" | Non-sparking, enclosed-break, or restricted-breathing design for Zone 2. |
| t (ta, tb, tc) | Protection by enclosure (Dust) | Dust-tight or dust-protected enclosure limiting surface temperature in dust zones. |
| h (c, b, k) | Non-electrical protection | Constructional safety (c), control of ignition sources (b), or liquid immersion (k) per GOST ISO 80079-36/37. |
3. Equipment Group & Subdivision
- Group I: Underground mines and surface installations susceptible to firedamp (methane and coal dust).
- Group II: Explosive gas atmospheres in surface industries:
- Subdivisions: IIA (Propane), IIB (Ethylene), IIC (Hydrogen / Acetylene – highest hazard).
- Group III: Explosive dust atmospheres:
- Subdivisions: IIIA (Combustible flyings), IIIB (Non-conductive dust), IIIC (Conductive dust).
4. Temperature Class & Special Suffixes ("X" and "U")
Defines the maximum permissible surface temperature of the equipment to prevent ignition of the surrounding gas/air mixture:
| Max Surface Temp (°C) | Temperature Class |
|---|---|
| ≤ 450 °C | T1 |
| ≤ 300 °C | T2 |
| ≤ 200 °C | T3 |
| ≤ 135 °C | T4 |
| ≤ 100 °C | T5 |
| ≤ 85 °C | T6 |
Example of a complete EAEU marking string: 1Ex db IIC T4 Gb X
Special suffixes: "X" indicates specific conditions for safe installation or operation detailed in the certificate and manual; "U" identifies an Ex component not intended for standalone use.
Overlapping Technical Regulations
Products subject to TR CU 012/2011 frequently fall under additional general EAEU Technical Regulations at the same time:
- TR CU 010/2011 On safety of machinery and equipment (for mechanical drives, pumps, fans, and industrial machines);
- TR CU 004/2011 On safety of low-voltage equipment (for electrical apparatus rated 50–1,000 V AC or 75–1,500 V DC);
- TR CU 020/2011 On electromagnetic compatibility (EMC) (for active electronic and electrical components);
- TR CU 032/2013 On safety of pressure equipment (for pressurized vessels, housings, and piping in hazardous locations).
In such cases, an EAC Ex Certificate covers the explosion-protection requirements under TR CU 012/2011, while a separate EAC Certificate or EAC Declaration is issued to confirm compliance with Machinery, Low-Voltage, EMC, or Pressure Equipment regulations.
Your Added Value with Schmidt & Schmidt: Sanctions-Compliant EAC Ex Certification
Obtaining an EAC Ex Certificate under TR CU 012/2011 requires coordinated engineering, accredited Ex testing, and strict adherence to international export control and sanctions rules (Regulation (EU) No 833/2014 and Swiss SECO regulations).
- Complete Russian Ex Dossier Compilation: Our engineers convert your ATEX/IECEx files into GOST-compliant Ex Technical Passports, Safety Justifications, Ignition Hazard Assessments, and Operation Manuals.
- Accredited Testing & Audits via Kazakhstan: We coordinate sample testing and ISO/IEC 80079-34 manufacturing audits through accredited Ex bodies in Kazakhstan (Sanctions Compliance) and serve as your independent Authorized Representative.
- Legally Secure Contracting in Euros: All contracts and invoices are handled transparently in Euros via our German headquarters in Passau, with timely courier delivery of all original certificates.
6 Steps to Your EAC Ex Certificate under TR CU 012/2011
Download TR CU 012/2011 On Safety of Equipment for Use in Explosive Atmospheres (Russian PDF)